Play the sample: Pressing the TEST button will play the original sample and resynthesized sounds together to aid the 'tuning' procedure.If you intend to have multiple Keyboard Zones use a sample that is in the middle of the Keyboard Zone range that it will serve (the same principle that is applied to Single sounds stretched across the keyboard. The note range C4-C5 also tends to work best for Reverb or delay effects are difficult for the resynthesis algorithm to interpret and often sound strange. Pad/String sounds are a good example to start with as they are usually the easiest to resynthesize. 'Load': Load the sample to be resynthesized by clicking the CHARGE SMP button.Reset the patch: Start with a blank patch, Left-click in the Program Name field (top-left window in Morphine) and select 'Reset Program' to call a blank patch.The sample, 'Aim' by adjusting the Resynthesis controls and 'Fire' by sending the sample to the desired Keyboard Zone. A good analogy to keep in mind when Resynthesizing is: 'Load, Aim and Fire'. The most accurate resynthesis will usually require your input, nothing can beat the human ear when matching sounds.

Remember this will overwrite any existing data in the Zone. SPECTRUM (Menu) - Use the menu item ' Import charged sample' to load the spectrum into the currently selected Zone.NOTE: The resynthesized sound heard here is a preview only (in order to reduce CPU load for testing).Īlways 'Import charged sample' (described below) to hear the final resynthesized sound. TEST - Starts/Stops a looped play-back of the original and resynthesized 'preview' sound.The default is a 50/50 mix of the original and resynthesized soundsĪnd is a good starting position as you use the Note & Detune controls to fine-tune the tone of the resynthesized sound to match the original. BALANCE - Adjust the TEST playback balance between the original sample (fully left) and the resynthesized sound (fully right).Changes to RESOLUTION will only be audible once the resynthesized sound has been loaded to a ZONE (see below). SPECTRUM menu item 'Import charged sample'. The Normal setting is the lowest resolution while Best has the highest and works in conjunction with the RESOLUTION - Changes the rate at which Breakpoints are laid down (similar to sample rate).Changes the tuning of the resynthesized sound in cents. This is similar to the 'Root Note' function in a Sampler and is the main control toĪdjust when matching the resynthesized sound with the original sample. NOTE - Change the root note of the resynthesized sound (the note that corresponds to the original pitch of the sound).Without effects and in the MIDI note range C4 to C5 for the best results. Clicking the button again when a sample is loaded will 'Uncharge' the sample, clearing it.


Detune software manual#
The tutorial at the bottom of this page has more details on manual tuning. For the most accurate results Morphine offers several manual controls to 'tune' the resynthesized sound to the original. Each Breakpoint represents a harmonic 'snapshot' of the sound at a given moment in
Detune software series#
The Resynthesis function takes an input sample and recreates the sound as a 'Spectrum' that is a series of Breakpoints.